10 Sites | Since 1995 | Read Worldwide
Anthem mrxslm
Anthem MRX SLM
DALI State of the Art
State of the Art
Naim
  • Sites
      • Back
      • SoundStage! Network (Here)
      • SoundStage! Access
      • SoundStage! Australia
      • SoundStage! Global
      • SoundStage! Hi-Fi
      • SoundStage! Life (podcast)
      • SoundStage! Simplifi
      • SoundStage! Solo
      • SoundStage! Ultra
      • SoundStage! Xperience
  • Videos
      • Back
      • Central
      • Encore
      • Expert
      • Icons
      • InSight
      • Lead-In
      • Real Hi-Fi
      • Shorts
      • Talks
      • Travelers
  • Newsletter
  • Buying Guides
      • Back
      • 2021 Equipment Buying Guide
      • 2020 Equipment Buying Guide
      • 2019 Equipment Buying Guide
      • 2018 Equipment Buying Guide
      • 2017 Equipment Buying Guide
      • 2016 Equipment Buying Guide
      • 2015 Equipment Buying Guide
      • 2014 Equipment Buying Guide
      • 2013 Equipment Buying Guide
      • 2012 Equipment Buying Guide
      • 2011 Equipment Buying Guide
      • 2010 Equipment Buying Guide
      • 2009 Equipment Buying Guide
  • Measurements
      • Back
      • Loudspeakers
      • Subwoofers
      • Amplifiers
      • Preamplifiers
      • Phono Preamplifiers
      • Digital-to-Analog Converters
      • Headphones
      • Headphone Amplifiers
  • Advertisers
  • Hiring

Sponsors

300x600 Vivid Audio Kaya 45 (202204)
300x600 Vivid Audio G2 (202204)

NRC Measurements: PSB Synchrony B600 Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 15 November 2021

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: 12″ up from bottom of cabinet
Grille: off

Frequency response and sensitivity

Sensitivity: 85.73dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Listening window

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Deviation from linearity

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Bowers & Wilkins 805 D4 Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 15 October 2021

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: between midrange-woofer and tweeter
Grille: off (midrange-woofer)

Frequency response and sensitivity

Sensitivity: 84.4dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Listening window

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Deviation from linearity

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Triangle 40th Anniversary Comète Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 15 September 2021

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: tweeter axis
Grille: off

Frequency response and sensitivity

Sensitivity: 88.0dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Listening window

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Deviation from linearity

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Paradigm Founder Series 100F Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 01 July 2021

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: between tweeter waveguide and midrange driver
Grille: off

Frequency response and sensitivity

Sensitivity: 88.9dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Chart C: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)
Additional measurement to show full frequency response with data supplied by Paradigm from 20Hz to 200Hz. The Paradigm-supplied data came from measurements taken in the company’s anechoic chamber, with the speaker measured over 360 degrees

Frequency response

Curve: on-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD 90dB

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Chart B: @ 95dB, 50Hz - 10kHz (measured @ 2m)

THD 95dB

Top curve: frequency response @ 95dB SPL
Bottom curve: THD+N @ 95dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Dev 90dB

Chart B: Difference @ 95dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Dev 95dB

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical Phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: KLH Albany II Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 01 June 2021

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: tweeter axis
Grille: off

Frequency response and sensitivity

Sensitivity: 86.7dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Listening window

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Deviation from linearity

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Focal Aria K2 936 Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 01 May 2021

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: center of midrange driver (except where noted)
Grille: off

Frequency response and sensitivity

Sensitivity: 89.7dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Chart C: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)
Additional measurement to show on-axis response with microphone pointed to tweeter axis

Frequency response

Curve: on-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD 90dB

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Chart B: @ 95dB, 50Hz - 10kHz (measured @ 2m)

THD 95dB

Top curve: frequency response @ 95dB SPL
Bottom curve: THD+N @ 95dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Dev 90dB

Chart B: Difference @ 95dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Dev 95dB

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical Phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Paradigm Monitor SE 8000F Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 15 April 2021

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: between tweeter waveguide and midrange driver
Grille: off

Frequency response and sensitivity

Sensitivity: 89.7dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD 90dB

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Chart B: @ 95dB, 50Hz - 10kHz (measured @ 2m)

THD 95dB

Top curve: frequency response @ 95dB SPL
Bottom curve: THD+N @ 95dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Dev 90dB

Chart B: Difference @ 95dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Dev 95dB

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical Phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Bowers & Wilkins 705 Signature Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 01 April 2021

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: between tweeter and midrange
Grille: n/a

Frequency response and sensitivity

Sensitivity: 85.3dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Listening window

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Deviation from linearity

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical phase

Vertical axis: phase
Horizontal axis: frequency

  1. NRC Measurements: Heavenly Soundworks FIVE17 Loudspeakers
  2. NRC Measurements: Aurelia XO Cerica XL Loudspeakers

Subcategories

Product Awards

Measurements

Equipment-Review Archives

The following categories containing listings of all product reviews published by the SoundStage! Network since 1995 from all of our online publications. The products are divided into categories and listed in descending order by date. There is no Search function within the listings, but you can search by bringing up the page with the appropriate list and using the "Find" command on your browser. (For Internet Explorer select: Edit > Find on this Page.)

Loudspeaker Measurements

Headphone Measurements

Subwoofer Measurements

Headphone Amplifier Measurements

Amplifier Measurements

Preamplifier Measurements

Phono Preamplifier Measurements

Digital-to-Analog Converter Measurements

Page 6 of 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

Us

Joseph Taylor
Geoffrey Morrison
Gordon Brockhouse
Edgar Kramer
Schneider
Dennis Burger
Jason Thorpe
Vivid Audio D26
Vivid Audio Kaya

This site is the main portal for
SoundStage!

All contents available on this website are copyrighted by SoundStage!® and Schneider Publishing Inc., unless otherwise noted. All rights reserved.

This site was designed by Rocket Theme, Karen Fanas, and The SoundStage! Network.
To contact us, please e-mail info@soundstagenetwork.com

To Top
Naim