10 Sites | Since 1995 | Read Worldwide
Anthem mrxslm
MartinLogan Abyss Series
DALI State of the Art
Wilson Audio
Naim
  • Sites
      • Back
      • SoundStage! Network (Here)
      • SoundStage! Access
      • SoundStage! Australia
      • SoundStage! Global
      • SoundStage! Hi-Fi
      • SoundStage! Life (podcast)
      • SoundStage! Simplifi
      • SoundStage! Solo
      • SoundStage! Ultra
      • SoundStage! Xperience
  • Videos
      • Back
      • Central
      • Encore
      • Expert
      • Icons
      • InSight
      • Lead-In
      • Real Hi-Fi
      • Shorts
      • Talks
      • Travelers
  • Newsletter
  • Buying Guides
      • Back
      • 2021 Equipment Buying Guide
      • 2020 Equipment Buying Guide
      • 2019 Equipment Buying Guide
      • 2018 Equipment Buying Guide
      • 2017 Equipment Buying Guide
      • 2016 Equipment Buying Guide
      • 2015 Equipment Buying Guide
      • 2014 Equipment Buying Guide
      • 2013 Equipment Buying Guide
      • 2012 Equipment Buying Guide
      • 2011 Equipment Buying Guide
      • 2010 Equipment Buying Guide
      • 2009 Equipment Buying Guide
  • Measurements
      • Back
      • Loudspeakers
      • Subwoofers
      • Amplifiers
      • Preamplifiers
      • Phono Preamplifiers
      • Digital-to-Analog Converters
      • Headphones
      • Headphone Amplifiers
  • Advertisers
  • Hiring

Sponsors

300x600 Vivid Audio G2 (202204)
300x600 Vivid Audio Kaya 45 (202204)

NRC Measurements: Dayton Audio Classic B65 Loudspeaker

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 15 September 2024

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Notes: Because of the low price and limited output capability of this loudspeaker, the THD+N and linearity measurements were performed at a sound-pressure level of 85dB instead of the usual 90dB to avoid damaging the drive units and/or crossover components with high voltage. Since those measured are performed and plotted at a 2-meter distance, that is equivalent to 91dB at 1 meter, which is still quite loud. In addition, we performed an extra measurement to show the on-axis performance without the supplied grille in place.

Setup

Microphone measuring position: tweeter axis
Grille: on (except where noted)

Frequency response and sensitivity

Sensitivity: 84.5dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Chart C: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)
Additional measurement to the on-axis frequency response with the supplied grille off

Frequency response

Curve: On-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total Harmonic Distortion + Noise

Chart A: @ 85dB, 50Hz - 10kHz (measured @ 2m)

THD+N

Top curve: frequency response @ 85dB SPL
Bottom curve: THD+N @ 85dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 85dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Deviation from linearity

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

electrical_phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Perlisten Audio R5t Loudspeaker

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 01 September 2024

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: 85.7cm up from bottom of cabinet (top of plinth)
Grille: n/a
Port plug: none

Frequency response and sensitivity

Sensitivity: 87.64B (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD 90dB

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Chart B: @ 95dB, 50Hz - 10kHz (measured @ 2m)

THD 95dB

Top curve: frequency response @ 95dB SPL
Bottom curve: THD+N @ 95dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Dev 90dB

Chart B: Difference @ 95dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Dev 95dB

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical Phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Totem Acoustic Bison Twin Tower Loudspeaker

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 01 August 2024

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: tweeter axis
Grille: off

Frequency response and voltage sensitivity

Voltage sensitivity: 87.98dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Listening window

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Deviation from linearity

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: GoldenEar T66 Loudspeaker

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 01 May 2024

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: 97.2″ up from top of aluminum base
Grille: on (non-removable)
Subwoofer Level dial: 12 o'clock (except as noted below)

Frequency response and sensitivity

Sensitivity: 89.23dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Chart C: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)
Additional measurement to show output with Subwoofer Level dial at 1 o'clock

Frequency response

Curve: on-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD 90dB

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Dev 90dB

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical Phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Estelon Aura Loudspeaker

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 01 April 2024

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: tweeter axis
Grille: off

Frequency response and voltage sensitivity

Voltage sensitivity: 86.35dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Listening window

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Deviation from linearity

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: PSB Imagine B50 Loudspeaker

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 01 April 2024

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: 12″ up from bottom of cabinet (manufacturer specified)
Grille: off

Frequency response and voltage sensitivity

Voltage sensitivity: 83.8dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Listening window

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Deviation from linearity

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Living Sounds Audio Statement 100 Loudspeaker

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 15 March 2024

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: middle of ribbon tweeter
Grille: off

Frequency response and sensitivity

Sensitivity: 78.9dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Chart C: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)
Additional measurement to show output of rear-mounted passive radiator with speaker turned 180 degrees

Frequency response

Curve: on-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD 90dB

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Dev 90dB

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical Phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: YG Acoustics Peaks Ascent Loudspeaker

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 15 February 2024

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: tweeter axis
Grille: n/a

Frequency response and voltage sensitivity

Voltage sensitivity: 84.2dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Listening window

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Deviation from linearity

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical phase

Vertical axis: phase
Horizontal axis: frequency

  1. NRC Measurements: Focal Vestia N°3 Loudspeaker
  2. NRC Measurements: Mission 770 Loudspeaker

Subcategories

Product Awards

Measurements

Equipment-Review Archives

The following categories containing listings of all product reviews published by the SoundStage! Network since 1995 from all of our online publications. The products are divided into categories and listed in descending order by date. There is no Search function within the listings, but you can search by bringing up the page with the appropriate list and using the "Find" command on your browser. (For Internet Explorer select: Edit > Find on this Page.)

Loudspeaker Measurements

Headphone Measurements

Subwoofer Measurements

Headphone Amplifier Measurements

Amplifier Measurements

Preamplifier Measurements

Phono Preamplifier Measurements

Digital-to-Analog Converter Measurements

Page 4 of 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

Us

Gordon Brockhouse
Jason Thorpe
Dennis Burger
Edgar Kramer
Geoffrey Morrison
Schneider
Joseph Taylor
Vitus Audio
Vitus Audio

This site is the main portal for
SoundStage!

All contents available on this website are copyrighted by SoundStage!® and Schneider Publishing Inc., unless otherwise noted. All rights reserved.

This site was designed by Rocket Theme, Karen Fanas, and The SoundStage! Network.
To contact us, please e-mail info@soundstagenetwork.com

To Top
Naim