10 Sites | Since 1995 | Read Worldwide
MartinLogan Abyss Series
Paradigm Founder Series
DALI State of the Art
Wilson Audio
Naim
  • Sites
      • Back
      • SoundStage! Network (Here)
      • SoundStage! Access
      • SoundStage! Australia
      • SoundStage! Global
      • SoundStage! Hi-Fi
      • SoundStage! Life (podcast)
      • SoundStage! Simplifi
      • SoundStage! Solo
      • SoundStage! Ultra
      • SoundStage! Xperience
  • Videos
      • Back
      • Central
      • Encore
      • Expert
      • Icons
      • InSight
      • Lead-In
      • Real Hi-Fi
      • Shorts
      • Talks
      • Travelers
  • Newsletter
  • Buying Guides
      • Back
      • 2021 Equipment Buying Guide
      • 2020 Equipment Buying Guide
      • 2019 Equipment Buying Guide
      • 2018 Equipment Buying Guide
      • 2017 Equipment Buying Guide
      • 2016 Equipment Buying Guide
      • 2015 Equipment Buying Guide
      • 2014 Equipment Buying Guide
      • 2013 Equipment Buying Guide
      • 2012 Equipment Buying Guide
      • 2011 Equipment Buying Guide
      • 2010 Equipment Buying Guide
      • 2009 Equipment Buying Guide
  • Measurements
      • Back
      • Loudspeakers
      • Subwoofers
      • Amplifiers
      • Preamplifiers
      • Phono Preamplifiers
      • Digital-to-Analog Converters
      • Headphones
      • Headphone Amplifiers
  • Advertisers
  • Hiring

Sponsors

300x600 Vivid Audio G2 (202204)
300x600 Vivid Audio Kaya 45 (202204)

NRC Measurements: Monitor Audio Bronze 6 Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 15 December 2015

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: between tweeter and midrange
Grille: off

Frequency response and sensitivity

Sensitivity: 87.3dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_on1530

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_456075

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_listeningwindow

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

thd_90db

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

dev_90db

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

electrical_phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Sonus Faber Chameleon T Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 15 November 2015

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: between tweeter and midrange
Grille: off

Frequency response and sensitivity

Sensitivity: 86.7dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_on1530

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_456075

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_listeningwindow

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

thd_90db

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

dev_90db

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

electrical_phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: PSB Imagine T3 Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 15 November 2015

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: tweeter axis
Grille: off

Frequency response and sensitivity

Sensitivity: 88.25dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_on1530

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_456075

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_listeningwindow

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

thd_90db

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Chart B: @ 95dB, 50Hz - 10kHz (measured @ 2m)

thd_95db

Top curve: frequency response @ 95dB SPL
Bottom curve: THD+N @ 95dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

dev_90db

Chart B: Difference @ 95dB from 70dB, 50Hz - 20kHz (measured @ 2m)

dev_95db

Impedance magnitude variation

impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

electrical_phase

Vertical axis: phase
Horizontal axis: frequency 

NRC Measurements: Focal Sopra No2 Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 01 October 2015

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: between tweeter and midrange
Grilles: off

Frequency response and sensitivity

Sensitivity: 87.5dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_on1530

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_456075

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_listeningwindow

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

thd_90db

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Chart B: @ 95dB, 50Hz - 10kHz (measured @ 2m)

thd_95db

Top curve: frequency response @ 95dB SPL
Bottom curve: THD+N @ 95dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

dev_90db

Chart B: Difference @ 95dB from 70dB, 50Hz - 20kHz (measured @ 2m)

dev_95db

Impedance magnitude variation

impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

electrical_phase

Vertical axis: phase
Horizontal axis: frequency 

NRC Measurements: GoldenEar Technology Triton Five Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 01 October 2015

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: middle of tweeter
Grille: on

Frequency response and sensitivity

Sensitivity: 87.7dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_on1530

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_456075

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_listeningwindow

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

thd_90db

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

dev_90db

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

electrical_phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Muraudio Domain Omni PX1 Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 15 September 2015

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Notes: The Domain Omni PX1’s 360-degree radiating pattern means that it directs much more energy to its sides and rear than does a front-firing loudspeaker. In an anechoic chamber, this side- and rear-directed energy is mostly absorbed -- something that wouldn’t happen in a typical listening room. Therefore, while the measured anechoic sensitivity of any loudspeaker will be lower than its in-room sensitivity, the difference between these sensitivities with the PX1 is significantly greater than with a front-firing loudspeaker.

The PX1’s very low anechoic sensitivity meant that the test equipment would not allow for the extremely high voltages needed to perform the tests of total harmonic distortion plus noise and deviation from linearity at our standard level of 90dB. Instead, we had to take both readings at a level of 85dB. This was not a limitation of the loudspeaker, but of the test equipment used.

The PX1’s responses varied depending on the axis; therefore, in addition to measuring the PX1’s response on axis, we also measured it at 60 degrees off axis.

Setup

Microphone measuring position: 39" up from bottom
Grille: n/a

Frequency response and sensitivity

Sensitivity: 72.1dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr on1530

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_456075

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window (on-axis)

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_listeningwindow

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Listening window (60-degrees off-axis)

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_listeningwindow

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 85dB, 50Hz - 10kHz (measured @ 2m)

thd_90db

Top curve: frequency response @ 85dB SPL
Bottom curve: THD+N @ 85dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 85dB from 70dB, 50Hz - 20kHz (measured @ 2m)

dev_90db

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

electrical_phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Bryston Mini A Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 01 July 2015

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: between tweeter and midrange
Grille: off

Frequency response and sensitivity

Sensitivity: 83.4dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_on1530

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_456075

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_listeningwindow

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total Harmonic Distortion + Noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

thd_90db

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

dev_90db

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

electrical_phase

Vertical axis: phase
Horizontal axis: frequency

NRC Measurements: Crystal Cable Arabesque Minissimo Loudspeakers

Details
Parent Category: Products
Category: Loudspeaker Measurements
Created: 01 June 2015

All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Note: Because of the low sensitivity of this loudspeaker, the THD+N and linearity measurements were performed at a sound-pressure level of 85dB instead of the usual 90dB to avoid damaging the drive units with high voltage.

Setup

Microphone measuring position: tweeter axis
Grille: off (none supplied)

Frequency response and sensitivity

Sensitivity: 81.0dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_on1530

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_456075

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

fr_listeningwindow

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total Harmonic Distortion + Noise

Chart A: @ 85dB, 50Hz - 10kHz (measured @ 2m)

thd_90db

Top curve: frequency response @ 85dB SPL
Bottom curve: THD+N @ 85dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 85dB from 70dB, 50Hz - 20kHz (measured @ 2m)

dev_90db

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

electrical_phase

Vertical axis: phase
Horizontal axis: frequency

  1. NRC Measurements: KEF R100 Loudspeakers
  2. NRC Measurements: Revel Performa3 M106 Loudspeakers

Subcategories

Product Awards

Measurements

Equipment-Review Archives

The following categories containing listings of all product reviews published by the SoundStage! Network since 1995 from all of our online publications. The products are divided into categories and listed in descending order by date. There is no Search function within the listings, but you can search by bringing up the page with the appropriate list and using the "Find" command on your browser. (For Internet Explorer select: Edit > Find on this Page.)

Loudspeaker Measurements

Headphone Measurements

Subwoofer Measurements

Headphone Amplifier Measurements

Amplifier Measurements

Preamplifier Measurements

Phono Preamplifier Measurements

Digital-to-Analog Converter Measurements

Page 13 of 59

  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

Us

Edgar Kramer
Dennis Burger
Joseph Taylor
Schneider
Jason Thorpe
Geoffrey Morrison
Gordon Brockhouse
Vitus Audio
Vitus Audio

This site is the main portal for
SoundStage!

All contents available on this website are copyrighted by SoundStage!® and Schneider Publishing Inc., unless otherwise noted. All rights reserved.

This site was designed by Rocket Theme, Karen Fanas, and The SoundStage! Network.
To contact us, please e-mail info@soundstagenetwork.com

To Top
Naim