All loudspeaker measurements are performed independently at the National Research Council of Canada. All measurement data and graphical information displayed below are the property of the SoundStage! Network and Schneider Publishing Inc. Reproduction in any format is not permitted.

Setup

Microphone measuring position: between tweeter waveguide and midrange driver
Grille: off

Frequency response and sensitivity

Sensitivity: 89.6dB (averaged 300Hz-3kHz on Listening Window, 2.83V/1m)

Chart A: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: on-axis response
Middle curve: 15 degrees off-axis response
Bottom curve: 30 degrees off-axis response

Chart B: 20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Top curve: 45 degrees off-axis response
Middle curve: 60 degrees off-axis response
Bottom curve: 75 degrees off-axis response

Listening window

20Hz - 20kHz (measured @ 2m, plotted @ 1m)

Frequency response

Response curve is an average of five measurements: on-axis, 15 degrees left and right off-axis, 15 degrees up and down off-axis

Total harmonic distortion + noise

Chart A: @ 90dB, 50Hz - 10kHz (measured @ 2m)

THD 90dB

Top curve: frequency response @ 90dB SPL
Bottom curve: THD+N @ 90dB (50Hz - 10kHz)

Chart B: @ 95dB, 50Hz - 10kHz (measured @ 2m)

THD 95dB

Top curve: frequency response @ 95dB SPL
Bottom curve: THD+N @ 95dB (50Hz - 10kHz)

Deviation from linearity

Chart A: Difference @ 90dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Dev 90dB

Chart B: Difference @ 95dB from 70dB, 50Hz - 20kHz (measured @ 2m)

Dev 95dB

Impedance magnitude variation

Impedance

Vertical axis: impedance
Horizontal axis: frequency

Electrical phase

Electrical Phase

Vertical axis: phase
Horizontal axis: frequency